SIZE 12 SHIELDED CONTACTS MIL-C-39029/75 TYPE
DEUTSCH PART NUMBERS 6162-217-1277 THRU  6162-224-1277

TERMINATION INSTRUCTIONS

1) SLIDE SHIELD CRIMP SLEEVE OVER CABLE END. (NOTE: IF SHIELD  CRIMP SLEEVE WILL NOT SLIDE BACK OVER CABLE INSULATION, INCREASE STRIP LENGTH  TO .765 + or - .010). STRIP WIRE TO DIMENSIONS SHOWN, MAKING SURE THE CUTS ARE CLEAN AND SQUARE. HOT WIRE STRIPPING IS RECOMMENDED.

diagram of shield crimp sleeve inserted over cable end
diagram showing correct wire stripping

2) SLIDE REAR  INSULATOR OVER INNER CONDUCTOR, LARGE DIAMETER FIRST. SLIDE INNER CONTACT CRIMP  BARREL OVER THE END OF THE INNER CONDUCTOR. CHECK TO SEE IF THE WIRE CAN BE SEEN THROUGH THE INSPECTION HOLE AND THAT THE INNER CONDUCTOR INSULATION IS BUTTED SQUARELY AGAINST THE REAR INSULATOR, AND THE REAR INSULATOR IS BUTTED SQUARELY AGAINST THE CRIMP BARREL. CRIMP INNER CONTACT USING A BASIC M22520/2-01 CRIMPING TOOL WITH M22520/2-34 POSITIONER.

rear insulator slides over inner conduction--diagram

3) SLIDE THE INSULATOR OVER THE INNER CONTACT UNTIL IT IS BOTTOMED.

slide insulator over inner contact--diagram

4) SLIDE OUTER SOCKET  CONTACT OVER INSULAT0R UNTIL IT IS BOTTOMED. (NOTE: DIMENSIONS GIVEN IN FIGURE).  COMB SHIELD BACK OVER OUTER SOCKET CONTACT AND POSITION THE SHIELD CRIMP SLEEVE OVER THE SHIELD APPROXIMATELY MIDWAY ALONG OUTER SOCKET CONTACT CRIMP BARREL. KEEPING THE CONTACTS SEATED PROPERLY, CRIMP THE SLEEVE USING A BASIC  M22520/31-01 CRIMPING TOOL AND M22520/ 31-02 POSITIONER. ROTATE TOOL AND CRIMP A  SECOND TIME.

slide outer socket contact over insulator--diagram

Deutsch Engineered Connecting Devices
250 Eddie Jones Way, Oceanside, CA (USA) 92058
Phone (760) 757-7500 FAX (760) 722-2476

Underwriters Laboratory Registration Mark signifying ISO 9000 Certification

 

Underwriters Laboratory Mark - ISO 14001 Certification

 

© Copyright 2007 Deutsch Engineered Connecting Devices.  All rights reserved.

ISO 14001 File A15714

Home About Us Contact Us CONNECTORS CONTACTS Product Guide Distributors Technical Papers Sitemap Request Drawing Webmaster